Our core expertise in the field of PWG results in excellent
operational performance for our API, Formulation clientele.
Achieve USP, UKMHRA, EU, IP, JP, WHO, GMP standardisation
with our highly customised systems.
Meticulous documentation of DQ, IQ, OQ, PQ, P&ID manuals
leads to ease in the validation process.
Highly customisable automation, using PLC – SCADA software
&pre-set modes such as – Production, Recirculation &
Hot water sanitization (or steam sanitization for WFI).
TOC: < 0.50 ppm (USP & EU)
Conductivity: < 1.3 µS/cm @ 25°C (USP), < 4.3 µS/cm @ 20°C (EU)
Nitrate (NO₃⁻): Nil (USP), < 0.20 ppm (EU)
Heavy Metals: Nil (USP), < 0.1 ppb (EU)
Aerobic Bacteria: < 100 CFU/ml (USP), < 100 CFU/ml (EU) MOC for all contact points with Purified Water generated: SS316 or SS316L. In-house orbital welding with third-party boroscopy certification. Velocity maintained at > 1 m/s.
Distribution line slope: 0.52 cm/m.
Conductivity sensor on return loop must have a dumping sensor & automation.
UV sterilization to be present at supply & return points.
Performance Qualification Check:
Quantitative: Actual output of PW system vs Design parameters (±5% permitted).
Qualitative: Source water, Water after chlorination (Free Chlorine), Soft water (pH & TH), Water before RO (FRC), Water after RO (TDS, Conductivity & pH), Water after EDI (Conductivity & pH), Water after UV (TBC).
Achieve consistent & top notch WFI for manufacturing parenteral
preparation by method of multicolumn distillation or comprehensive
membrane separation.
Achieve USP, UKMHRA, Eur.Ph, IP, JP, WHO, GMP standardisation
with our highly customised systems.
Meticulous documentation of DQ, IQ, OQ, PQ, P&ID manuals leads
to ease in the validation process.
TOC: < 0.50 ppm (USP & EU)
Conductivity: < 1.3 µS/cm @ 25°C (USP), < 4.3 µS/cm @ 20°C (EU)
Nitrate (NO₃⁻): Nil (USP), < 0.20 ppm (EU)
Heavy Metals: Nil (USP), < 0.1 ppb (EU)
Aerobic Bacteria: < 100 CFU/ml (USP), < 100 CFU/ml (EU) MOC for all contact points with Purified Water generated: SS316 or SS316L. In-house orbital welding with third-party boroscopy certification. Velocity maintained at > 1 m/s.
Distribution line slope: 0.52 cm/m.
Conductivity sensor on return loop must have a dumping sensor & automation.
UV sterilization to be present at supply & return points.
Performance Qualification Check:
Quantitative: Actual output of PW system vs Design parameters (±5% permitted).
Qualitative: Source water, Water after chlorination (Free Chlorine), Soft water (pH & TH), Water before RO (FRC), Water after RO (TDS, Conductivity & pH), Water after EDI (Conductivity & pH), Water after UV (TBC).