VALIDATION CHECK POINTS

TOC: < 0.50 ppm (USP & EU)

Conductivity: < 1.3 µS/cm @ 25°C (USP), < 4.3 µS/cm @ 20°C (EU)

Nitrate (NO₃⁻): Nil (USP), < 0.20 ppm (EU)

Heavy Metals: Nil (USP), < 0.1 ppb (EU)

Aerobic Bacteria: < 100 CFU/ml (USP), < 100 CFU/ml (EU) MOC for all contact points with Purified Water generated: SS316 or SS316L. In-house orbital welding with third-party boroscopy certification. Velocity maintained at > 1 m/s.

Distribution line slope: 0.52 cm/m.

Conductivity sensor on return loop must have a dumping sensor & automation.

UV sterilization to be present at supply & return points.

Performance Qualification Check:

Quantitative: Actual output of PW system vs Design parameters (±5% permitted).

Qualitative: Source water, Water after chlorination (Free Chlorine), Soft water (pH & TH), Water before RO (FRC), Water after RO (TDS, Conductivity & pH), Water after EDI (Conductivity & pH), Water after UV (TBC).

WFI GENERATION SYSTEM SPECIFICATIONS

Achieve consistent & top notch WFI for manufacturing parenteral
preparation by method of multicolumn distillation or comprehensive
membrane separation.

Achieve USP, UKMHRA, Eur.Ph, IP, JP, WHO, GMP standardisation
with our highly customised systems.

Meticulous documentation of DQ, IQ, OQ, PQ, P&ID manuals leads
to ease in the validation process.

VALIDATION CHECK POINTS

TOC: < 0.50 ppm (USP & EU)

Conductivity: < 1.3 µS/cm @ 25°C (USP), < 4.3 µS/cm @ 20°C (EU)

Nitrate (NO₃⁻): Nil (USP), < 0.20 ppm (EU)

Heavy Metals: Nil (USP), < 0.1 ppb (EU)

Aerobic Bacteria: < 100 CFU/ml (USP), < 100 CFU/ml (EU) MOC for all contact points with Purified Water generated: SS316 or SS316L. In-house orbital welding with third-party boroscopy certification. Velocity maintained at > 1 m/s.

Distribution line slope: 0.52 cm/m.

Conductivity sensor on return loop must have a dumping sensor & automation.

UV sterilization to be present at supply & return points.

Performance Qualification Check:

Quantitative: Actual output of PW system vs Design parameters (±5% permitted).

Qualitative: Source water, Water after chlorination (Free Chlorine), Soft water (pH & TH), Water before RO (FRC), Water after RO (TDS, Conductivity & pH), Water after EDI (Conductivity & pH), Water after UV (TBC).

Services

PREVENTIVE MAINTENANCE CONTRACT

SYSTEM PERFORMANCE CHECK

ONLINE MONITORING SYSTEMS

Industries

SEMICONDUCTERS

PHARMACEUTICAL & NUTRACEUTICAL

TEXTILE & POLYESTER YARN

PETROCHEMICALS

ELECTROPLATING

PULP & PAPER

Learn more

Careers

Blog

News

Contact

Contact

Ahura Aquatech Private Limited
1st Floor, Survey No. 720/1 to 4, 720/9 & 720/19,
Somnath Road, Dabhel, Nani Daman,
Daman – 396210,
Dadra & Nagar Haveli and Daman & Diu, India.

+91 7777034405
burjizmotashaw95@gmail.com