Home / INDUSTRY / Pharmaceutical & Nutraceutical / Purified Water Generation System
PHARMACEUTICAL & NUTRACEUTICALS
Purified Water
Generation System
Our core expertise in Purified Water generation delivers excellent operational performance for our API and formulation clientele.
Highly customisable PLC–SCADA automation with pre-set modes for production, recirculation and hot-water sanitization.
STANDARDISATION & COMPLIANCE
AUTOMATION MODES · PLC · SCADA
- Production
- Recirculation
- Hot-Water Sanitization
ENGINEERING & CONSTRUCTION
Contact MOC
SS316 / SS316L
Loop velocity
> 1 m/s
Distribution slope
0.52 cm/m
Welding
Orbital + boroscopy
UV sterilisation
Supply & return
Return loop
Conductivity dump valve
VALIDATION CHECK POINTS
| Parameter | USP | EU |
|---|---|---|
| TOC | < 0.50 ppm | < 0.50 ppm |
| Conductivity | < 1.3 µS/cm @25°C | < 4.3 µS/cm @20°C |
| Nitrate (NO₃) | Nil | < 0.20 ppm |
| Heavy Metals | Nil | < 0.1 ppb |
| Aerobic Bacteria | <100 CFU/ml | <100 CFU/ml |
PERFORMANCE QUALIFICATION
Quantitative : Actual output vs design parameters — ± 5% permitted.
Quantitative : Source → post-chlorination (free Cl)
→ soft water (pH, TH)
→ pre-RO (FRC)
→ post-RO (TDS, cond, pH)
→ post-EDI (cond, pH)
→ post-UV (TBC)